Rated performance
From the spec sheet on file for model CH-RHP48LCU-230VO. Every other figure is in the full spec sheet below.
- Capacity
48,000BTU/h
Cooling runs 6,700 to 53,500 BTU/h
- Efficiency
18.5SEER2
Bar on the catalog's 14 to 28 range
- Sound
65dB(A)
Outdoor unit, at full speed
- Heating
−22°F
Lowest outdoor temperature, manufacturer rating
- Line set
246ft max
3/8 in and 3/4 in lines, 98.4 ft max rise
- HSPF2
10.1
Heating efficiency, region IV
- Cooling
- −22 to 122 °F
- Heating
- −22 to 75 °F
Why this outdoor unit
From the feature list on file for model CH-RHP48LCU-230VO.
- Refrigerant Sensor
- Humidity Sensor
- GoldFin Anti-Corrosive Coating
- Multiple Fan Speeds
- Easy service
- TU1 Cooper Coil
- Can be applied horizontally from the ceiling or
- Inverter technology
Specifications
The full spec sheet
Every value on file for model CH-RHP48LCU-230VO, with units.
Capacity
5 values| Nominal capacity | 48,000 | BTU/h |
|---|---|---|
| Rated cooling capacity | 48,000 | BTU/h |
| Cooling capacity range | 11,000 to 56,500 | BTU/h |
| Rated heating capacity (47°F) | 52,000 | BTU/h |
| Heating capacity range (47°F) | 11,200 to 60,000 | BTU/h |
From the Cooper & Hunter spec sheet.
Efficiency
5 values| SEER2 | 16.7 | |
|---|---|---|
| EER2 | 10.4 | |
| HSPF2 (Region IV) | 10.8 | |
| HSPF2 (Region V, cold climate) | 8.8 | |
| COP at 47°F | 3.6 | W/W |
From the Cooper & Hunter spec sheet.
Electrical
9 values| Voltage | 208/230 | V |
|---|---|---|
| Phase | 1 | ph |
| Frequency | 60 | Hz |
| Operating voltage range | 187 to 253 | V |
| Minimum circuit ampacity (MCA) | 44 | A |
| Maximum fuse / breaker size | 45 | A |
| Rated cooling current | 24.2 | A |
| Indoor/outdoor communication wire gauge | 14 | AWG |
| Indoor/outdoor communication wire conductors | 3 |
From the Cooper & Hunter spec sheet, with 3 values from the product listing.
Refrigerant and piping
8 values| Refrigerant | R-454B | |
|---|---|---|
| Pre-charged for line length up to | 25 | ft |
| Additional charge per extra foot, 3/8 in. liquid line | 0.32 | oz/ft |
| Liquid line size | 3/8 | in |
| Suction (gas) line size | 3/4 | in |
| Maximum line length | 246 | ft |
| Maximum height difference, indoor to outdoor | 98.4 | ft |
| Compressor type | Twin rotary |
From the Cooper & Hunter spec sheet, with 1 value from the product listing.
Dimensions and weight
8 values| Width | 37.48 | in |
|---|---|---|
| Depth | 16.34 | in |
| Height | 52.48 | in |
| Net weight | 208.8 | lb |
| Shipping width | 43.11 | in |
| Shipping depth | 19.49 | in |
| Shipping height | 57.48 | in |
| Shipping weight | 239.9 | lb |
From the Cooper & Hunter spec sheet.
Sound and airflow
1 value| Outdoor sound level | 65 | dB(A) |
|---|
From the Cooper & Hunter spec sheet.
Operating range
2 values| Outdoor operating range, cooling | -22 to 122 | °F |
|---|---|---|
| Outdoor operating range, heating | -22 to 75 | °F |
From the Cooper & Hunter spec sheet.
Controls and features
1 value| Zones | Single zone |
|---|
From the Cooper & Hunter spec sheet.
Approved pairings
Indoor heads approved for this unit.
This outdoor unit runs one indoor head. These 5 heads are approved for it by Cooper & Hunter.
| Unit | Size |
|---|---|
48K Ceiling CassetteCH-RH48LCCT | 48K BTU |
48K Multi-Position Air HandlerCH-RS48LCAHU | 48K BTU |
48K Slim DuctCH-RS48LCDT-HS | 48K BTU |
48K Ceiling CassetteCH-RSH48LCCT | 48K BTU |
48K Universal Floor/CeilingCH-RSH48LCFC | 48K BTU |
Rebates
Heat pump rebates by ZIP code
Utility and state programs change by ZIP code and can be large. Enter yours to see the programs on file for this model.
See the biggest programs by stateAbout this outdoor unit
What it is and what it needs.
The Cooper & Hunter Hyper Outdoor 48K Outdoor Unit is a 48K BTU single-zone outdoor unit: it runs one matching indoor head. 5 indoor units are approved for it by the manufacturer and listed on this page.
It runs on 208–230 V and uses R454B refrigerant. It is rated SEER2 18.5.
Documents
- Spec sheetCH-RHP48LCU-230VO with CH-RS48LCDT-HS(PDF, opens in a new tab)
- Spec sheetCH-RHP48LCU-230VO with CH-RSH48LCFC(PDF, opens in a new tab)
- Spec sheetCH-RHP48LCU-230VO with CH-RH48LCCT(PDF, opens in a new tab)
- Spec sheetCH-RHP48LCU-230VO with CH-RSH48LCCT(PDF, opens in a new tab)
- Spec sheetCH-RHP48LCU-230VO with CH-RS48LCDT-HS(PDF, opens in a new tab)
- Installation manualR454B Outdoor units(PDF, opens in a new tab)
- Product leafletSlimDuct R454B(PDF, opens in a new tab)
- Document(PDF, opens in a new tab)
Call before you order.Sizing, pairings, line set lengths and rebates.
Monday to Friday, 8 AM to 5 PM Central
We are in Mountain Grove, Missouri.
Send a messageQuestions
Before you order
Anything else, call (417) 812-0015. Monday to Friday, 8 AM to 5 PM Central.
Is this the whole system?
This is the outdoor unit (condenser). Pair it with one of the approved indoor units listed above. Line sets and brackets are quoted with your order; call and we add them.
Can I install it myself?
Mounting, wiring and running the line set are within reach of a capable DIYer. The refrigerant connection and vacuum should be done by a licensed HVAC technician in most states, and manufacturer warranties usually require it. We can point you to an installer in your area.
What if I am not sure about the size?
Room size, ceiling height, insulation, windows and sun exposure all change the answer. Call (417) 812-0015 with the room details and we will confirm the BTU rating before you order.
Can I return it?
No. All sales are final, so size it right first: the builder and the sizing guide are free, and a person confirms the pairing on every order. If anything arrives damaged, we handle the claim for you, and defects are covered by the manufacturer warranty.
What refrigerant does it use?
R454B. Match it to any existing equipment or line set you plan to reuse; refrigerants are not interchangeable.
Reviews
From verified buyers only
No reviews for this unit yet.
We publish reviews from verified orders only. Buyers are invited to write one after delivery, and a person reads each review before it appears here.
Not sure about the size? Check it in the builder.
The builder sizes each room and shows only approved Cooper & Hunter systems. All sales are final, so size it right first.
Monday to Friday, 8 AM to 5 PM Central