Heats and coolsR454B
Hyper Heat, Multi-zone outdoor unit
Hyper Heat 55K Multi-Zone Outdoor Unit, with Shut-off Valves
A person checks every order before it ships.
Rebates for this unitUtility and state programs change by ZIP code.
- Ships to all 50 states. If anything arrives damaged, we handle the claim.
- New units from an authorized Cooper & Hunter dealer, with the full factory warranty.
- All sales are final. Not sure about the size? Call (417) 812-0015 before you order.
Rated performance
From the spec sheet on file for model CH-RVHP55M-230VO. Every other figure is in the full spec sheet below.
- Capacity
55,000BTU/h
Cooling runs 19,000 to 59,000 BTU/h
- Zones
6
Runs up to 6 indoor heads
- Efficiency
22.2SEER2
Bar on the catalog's 14 to 28 range
- Sound
65dB(A)
Outdoor unit, at full speed
- Heating
−22°F
Lowest outdoor temperature, manufacturer rating
- HSPF2
10.5
Heating efficiency, region IV
- Cooling
- −22 to 122 °F
- Heating
- −22 to 75 °F
Specifications
The full spec sheet
Every value on file for model CH-RVHP55M-230VO, with units.
Capacity
5 values| Nominal capacity | 55,000 | BTU/h |
|---|---|---|
| Rated cooling capacity | 51,000 | BTU/h |
| Cooling capacity range | 19,000 to 59,000 | BTU/h |
| Rated heating capacity (47°F) | 55,000 | BTU/h |
| Heating capacity range (47°F) | 20,000 to 59,000 | BTU/h |
From the Cooper & Hunter spec sheet.
Efficiency
5 values| SEER2 | 22.2 | |
|---|---|---|
| EER2 | 12 | |
| HSPF2 (Region IV) | 10.5 | |
| HSPF2 (Region V, cold climate) | 8.5 | |
| COP at 47°F | 3.5 | W/W |
From the Cooper & Hunter spec sheet.
Electrical
6 values| Voltage | 208/230 | V |
|---|---|---|
| Phase | 1 | ph |
| Frequency | 60 | Hz |
| Operating voltage range | 187 to 253 | V |
| Minimum circuit ampacity (MCA) | 39.5 | A |
| Maximum fuse / breaker size | 40 | A |
From the Cooper & Hunter spec sheet.
Refrigerant and piping
8 values| Refrigerant | R-454B | |
|---|---|---|
| Pre-charged for line length up to | 150 | ft |
| Additional charge per extra foot, 1/4 in. liquid line | 0.16 | oz/ft |
| Additional charge per extra foot, 3/8 in. liquid line | 0.32 | oz/ft |
| Liquid line connections | 6 × 1/4 in | |
| Gas line connections | 4 × 3/8 in + 2 × 1/2 in | |
| Indoor unit connections | 6 | |
| Maximum height difference, indoor to outdoor | 49.2 | ft |
From the Cooper & Hunter spec sheet.
Dimensions and weight
8 values| Width | 37.48 | in |
|---|---|---|
| Depth | 16.34 | in |
| Height | 52.48 | in |
| Net weight | 246.5 | lb |
| Shipping width | 43.11 | in |
| Shipping depth | 19.49 | in |
| Shipping height | 58.27 | in |
| Shipping weight | 276.7 | lb |
From the Cooper & Hunter spec sheet.
Sound and airflow
1 value| Outdoor sound level | 65 | dB(A) |
|---|
From the Cooper & Hunter spec sheet.
Operating range
2 values| Outdoor operating range, cooling | -22 to 122 | °F |
|---|---|---|
| Outdoor operating range, heating | -22 to 75 | °F |
From the Cooper & Hunter spec sheet.
Controls and features
2 values| Zones | Multi zone |
|---|---|
| Heating performance | Hyper Heat |
From the Cooper & Hunter spec sheet.
Certifications
2 values| AHRI certified | Yes |
|---|---|
| AHRI reference numbers | 215864281 (Ducted), 215864282 (Non-Ducted), 215864283 (Mixed) |
From the Cooper & Hunter spec sheet.
Rebates
Heat pump rebates by ZIP code
Utility and state programs change by ZIP code and can be large. Enter yours to see the programs on file for this model.
See the biggest programs by stateAbout this outdoor unit
What it is and what it needs.
The Cooper & Hunter Hyper Heat 55K Multi-Zone Outdoor Unit, with Shut-off Valves is a 55K BTU multi-zone outdoor unit that runs up to 6 indoor heads from one condenser. Call and we confirm the matching indoor unit before you order.
It runs on 208–230 V and uses R454B refrigerant. It is rated SEER2 22.2. The manufacturer rates it to keep heating at outdoor temperatures down to -22 °F.
Documents
- Spec sheetCH-RVHP55M-230VO(PDF, opens in a new tab)
- Installation manualMulti R(PDF, opens in a new tab)
- Installation manualRVHP Multi Zone Units(PDF, opens in a new tab)
- DocumentCH-RVHP55M-230VO (Non ducted)(PDF, opens in a new tab)
- DocumentCH-RVHP55M-230VO (Ducted)(PDF, opens in a new tab)
- Document(PDF, opens in a new tab)
Call before you order.Sizing, pairings, line set lengths and rebates.
Monday to Friday, 8 AM to 5 PM Central
We are in Mountain Grove, Missouri.
Send a messageQuestions
Before you order
Anything else, call (417) 812-0015. Monday to Friday, 8 AM to 5 PM Central.
Is this the whole system?
This is the multi-zone outdoor unit. It runs up to 6 indoor heads from the approved list above; each head is ordered separately. Line sets and brackets are quoted with your order; call and we add them.
Can I install it myself?
Mounting, wiring and running the line set are within reach of a capable DIYer. The refrigerant connection and vacuum should be done by a licensed HVAC technician in most states, and manufacturer warranties usually require it. We can point you to an installer in your area.
What if I am not sure about the size?
Room size, ceiling height, insulation, windows and sun exposure all change the answer. Call (417) 812-0015 with the room details and we will confirm the BTU rating before you order.
Can I return it?
No. All sales are final, so size it right first: the builder and the sizing guide are free, and a person confirms the pairing on every order. If anything arrives damaged, we handle the claim for you, and defects are covered by the manufacturer warranty.
What refrigerant does it use?
R454B. Match it to any existing equipment or line set you plan to reuse; refrigerants are not interchangeable.
Reviews
From verified buyers only
No reviews for this unit yet.
We publish reviews from verified orders only. Buyers are invited to write one after delivery, and a person reads each review before it appears here.
Not sure about the size? Check it in the builder.
The builder sizes each room and shows only approved Cooper & Hunter systems. All sales are final, so size it right first.
Monday to Friday, 8 AM to 5 PM Central